RR Kabel H05Z-K & H07Z-K – Halogen-Free LSOH Single Core Wiring Cable

  • Wiring of lighting fixtures & lighting units
  • Switchboards & distributor internal wiring
  • Enclosed installation ducts
  • On / in / beneath plaster installations (dry environments)
  • Rail-coach wiring (up to 900V DC against ground)
  • Public buildings, hospitals & high-occupancy facilities
  • UAE buildings where LSOH fire safety is required
SKU RR-KABEL-H05Z-K-H07Z-K-HALOGEN-FREE-LSOH-SINGLE-CORE-WIRING-CABLE Category Tag Brand:
[enquiry_now_button]

The RR Kabel H05Z-K and H07Z-K are halogen-free, low smoke zero halogen (LSOH) single-core flexible wiring cables built to BS EN 50525-3-41, designed for installation in dry environments where protecting valuable assets from fire damage is a critical priority. These cables are used for wiring lighting fixtures, switchboards, distributors, and enclosed installation ducts where the release of toxic halogen gases during a fire would be unacceptable — making them the preferred choice in public buildings, hospitals, transport hubs, and high-value facilities across the UAE. The H05Z-K (300/500V) covers sections from 0.5mm² to 1mm², while the H07Z-K (450/750V) covers 1.5mm² to 240mm², together spanning the complete range of single-core wiring requirements. Direct operating voltages up to 900V against ground are permitted for rail-coach applications, and for inner wiring of switchboards and distributors, these cables handle alternating nominal voltages up to 1000V or direct voltages up to 750V against ground. The Class 5 flexible plain/metal coated stranded copper conductor is insulated with cross-linked Polyolefin EI5 (EN 50363-5), delivering excellent smoke density, halogen-free, corrosivity, and ozone-resistant properties. Available in 12 colour options and two conductor types. Certified REACH, RoHS, and CE.

Technical Specifications & Size Variations

Specification Details
Standard BS EN 50525-3-41
Certifications REACH
RoHS
CE
Nominal Voltage H05Z-K: Uo/U 300/500V (sections 0.5mm² to 1mm²)
H07Z-K: Uo/U 450/750V (sections 1.5mm² to 240mm²)
Temperature Range -15°C to +90°C
Test Voltage 2500V
Conductor Class 5 flexible plain/metal coated stranded — EN 60228
Type 0 = Annealed Bare Copper (ABC)
Type 1 = Annealed Tinned Copper (ATC)
Insulation Polyolefin cross-linked EI5 — EN 50363-5
Insulation Type LSOH = Low Smoke Zero Halogen-Free
Bending Radius Cable Ø ≤ 8mm: 4× outer diameter
Approx. Ø > 8 to 12mm: 5× outer diameter
Approx. Ø > 12mm: 6× outer diameter

TESTS PASSED

Specification Details
Smoke density EN 61034-2
Halogen free EN 50525-1
EN 60754-1
Corrosivity EN 60754-2
Ozone resistant EN 60811-2-1
Flame retardant EN 60332-1-2 (self-extinguishing)
Specification Details
COLOURS AVAILABLE (suffix ‘xx’ in part number) 01-Green
02-Black
03-Red
04-Blue
05-Yellow
06-Green/Yellow
07-White
08-Violet
09-Brown
10-Orange
11-Pink
12-Grey
Part Number Type Section (Sq. mm) Insul. Thick(mm) Overall Ø (mm) Lower / Upper Weight kg/km
02040101xx6c H05Z-K 0.5 0.6 1.9 / 2.4 9
02040102xx6c H05Z-K 0.75 0.6 2.1 / 2.6 12
02040103xx6c H05Z-K 1.0 0.6 2.2 / 2.8 15
02040104xx6c H07Z-K 1.5 0.7 2.8 / 3.5 21
02040105xx6c H07Z-K 2.5 0.8 3.4 / 4.3 33
02040106xx6c H07Z-K 4.0 0.8 3.9 / 4.9 47
02040107xx6c H07Z-K 6.0 0.8 4.4 / 5.5 66
02040108xx6c H07Z-K 10 1.0 5.7 / 7.1 112
02040109xx6c H07Z-K 16 1.0 6.7 / 8.4 169
02040110xx6c H07Z-K 25 1.2 8.4 / 10.6 260
02040111xx6c H07Z-K 35 1.2 9.7 / 12.1 358
02040112xx6c H07Z-K 50 1.4 11.5 / 14.4 509
02040113xx6c H07Z-K 70 1.4 13.2 / 16.61 701
02040114xx6c H07Z-K 95 1.6 15.1 / 18.8 925
02040115xx6c H07Z-K 120 1.6 16.7 / 20.9 1,168
02040116xx6c H07Z-K 150 1.8 18.6 / 23.3 1,456
02040117xx6c H07Z-K 185 2.0 20.6 / 25.8 1,773
02040118xx6c H07Z-K 240 2.2 23.5 / 29.4 2,329